{"id":13517,"date":"2026-02-02T17:21:54","date_gmt":"2026-02-02T17:21:54","guid":{"rendered":"https:\/\/www.sygnaturediscovery.com\/?post_type=technical-note&#038;p=13517"},"modified":"2026-02-02T17:25:41","modified_gmt":"2026-02-02T17:25:41","slug":"thermodynamic-solubility-assay-validation","status":"publish","type":"technical-note","link":"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/","title":{"rendered":"Thermodynamic Solubility"},"content":{"rendered":"\n<h2 class=\"wp-block-heading has-text-2-xl-font-size\">About the Assay<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sygnature Discovery\u2019s thermodynamic solubility assay determines the equilibrium solubility of drug molecules across physiologically relevant media, providing essential data for understanding absorption, formulation feasibility and developability. Solubility is defined as the amount of compound that dissolves in a solvent under set conditions. Unlike kinetic solubility approaches, the thermodynamic method incorporates excess solid material and allows the system to reach equilibrium, giving a more reliable assessment of intrinsic solubility.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The assay evaluates compound solubility in pH\u202f7.4 phosphate buffer alongside three biorelevant simulated fluids: FaSSIF, FeSSIF and FaSSGF, representing fasted small intestine, fed small intestine and fasted gastric conditions. These environments capture solubility shifts driven by bile salts, fed\u2011state lipids and pH.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The method supports reproducible measurements across diverse media, facilitating comparison of solubility behavior under physiological conditions. Thermodynamic solubility data are widely used to guide medicinal chemistry optimization, predict oral absorption and inform formulation strategies in early drug discovery.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-2-xl-font-size\" style=\"padding-top:var(--wp--preset--spacing--20)\">Protocol Summary<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The thermodynamic solubility workflow begins by adding excess compound to an aqueous medium, allowing the system to reach equilibrium. Samples are incubated in sealed vials with continuous mixing to ensure consistent exposure of solid and dissolved phases throughout the incubation period (24 hours). After equilibrium is achieved, aliquots are removed and filtered to separate dissolved material from any remaining solid.<br><br>The filtered samples undergo appropriate dilution to fall within the analytical calibration range and are quantified using LC\u2013MS\/MS. Calibration standards prepared from a 10 mM DMSO stock enable accurate quantification across a wide solubility range.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-2-xl-font-size\" style=\"padding-top:var(--wp--preset--spacing--20)\">Validation Results<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Validation results demonstrated strong reproducibility across all media assessed, with consistent solubility measurements obtained between studies and within assays. Test compounds were selected to cover a broad solubility range, enabling assessment of assay performance across low, moderate and highly soluble substances. Nine test compounds were profiled in pH\u202f7.4 buffer, spanning low\u2011solubility materials such as Albendazole to highly soluble compounds like Chlorzoxazone and Diclofenac (&gt;1000\u202f\u00b5M). Coefficients of variation were generally low, confirming the robustness of the equilibrium solubility determination. The resulting solubility measurements were in good agreement with literature sources (figure 1). Intra\u2011assay assessments supported similar trends, with Albendazole, Ketoconazole and Haloperidol demonstrating reproducible results across six independent incubations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To evaluate matrix\u2011dependent effects, solubility was also measured in FaSSIF, FeSSIF and FaSSGF media. Compounds exhibited solubility enhancements consistent with biorelevant media properties\u2014for example, Ketoconazole (24.8 \u00b5M) and Haloperidol (350.2 \u00b5M) showed substantial increases in FaSSIF relative to pH 7.4 buffer. The assay reliably quantified solubility increases across all media types while maintaining acceptable variability.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-style-rounded-large is-style-rounded-large--1\"><img loading=\"lazy\" decoding=\"async\" width=\"847\" height=\"462\" src=\"https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5.webp\" alt=\"\" class=\"wp-image-13518\" srcset=\"https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5.webp 847w, https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5-300x164.webp 300w, https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5-768x419.webp 768w, https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5-640x349.webp 640w\" sizes=\"(max-width: 847px) 100vw, 847px\"><\/figure>\n\n\n\n<p class=\"has-text-sm-font-size wp-block-paragraph\" style=\"padding-top:var(--wp--preset--spacing--20)\"><em><strong>Figure 1.<\/strong> <em>Graph illustrating the mean inter-assay Thermodynamic Solubility results generated in pH7.4 buffer in comparison to literature sources <sup>(1,2)<\/sup><\/em><\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-2-xl-font-size\" style=\"padding-top:var(--wp--preset--spacing--20)\">Summary<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This assay provides a robust, standardized procedure suitable for high\u2011confidence solubility estimation. The use of multiple biorelevant media allows the assay to capture physiologically meaningful solubility differences, supporting compound triage, formulation selection and mechanistic interpretation of absorption\u2011related behaviors. Reproducibility across studies ensures that solubility values can be reliably compared across batches and compounds.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-text-xl-font-size\" style=\"padding-top:var(--wp--preset--spacing--20)\">References<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Tom\u00e1s Sou, Christel A.S. Bergstr\u00f6m: Automated assays for thermodynamic (equilibrium) solubility determination<\/li>\n\n\n\n<li>Mark C. Wenlock, Rupert P. Austin, Tim Potter, and Patrick Barton: A Highly Automated Assay for Determining the Aqueous Equilibrium Solubility of Drug Discovery Compounds<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Sygnature Discovery\u2019s thermodynamic solubility validation confirms a robust, equilibrium\u2011based method for generating high\u2011confidence solubility data across pH 7.4 buffer and biorelevant media including FaSSIF, FeSSIF and FaSSGF. The assay demonstrates strong reproducibility, good agreement with literature values and clear compound\u2011dependent solubility shifts, supporting absorption prediction, medicinal chemistry optimisation and formulation strategy development.<\/p>\n","protected":false},"featured_media":0,"template":"","category":[683,719],"resource_tag":[],"class_list":["post-13517","technical-note","type-technical-note","status-publish","hentry","category-dmpk","category-physicochemical-profiling"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Thermodynamic Solubility: Equilibrium Across Biorelevant Media<\/title>\n<meta name=\"description\" content=\"Thermodynamic solubility assay providing reliable equilibrium solubility measurements to support absorption and formulation decisions.\" \/>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"fr_CA\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Thermodynamic Solubility: Equilibrium Across Biorelevant Media\" \/>\n<meta property=\"og:description\" content=\"Thermodynamic solubility assay providing reliable equilibrium solubility measurements to support absorption and formulation decisions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/\" \/>\n<meta property=\"og:site_name\" content=\"Sygnature\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-02T17:25:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"847\" \/>\n\t<meta property=\"og:image:height\" content=\"462\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimation du temps de lecture\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/technical-note\\\/thermodynamic-solubility-assay-validation\\\/\",\"url\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/technical-note\\\/thermodynamic-solubility-assay-validation\\\/\",\"name\":\"Thermodynamic Solubility: Equilibrium Across Biorelevant Media\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/technical-note\\\/thermodynamic-solubility-assay-validation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/technical-note\\\/thermodynamic-solubility-assay-validation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/image-5.webp\",\"datePublished\":\"2026-02-02T17:21:54+00:00\",\"dateModified\":\"2026-02-02T17:25:41+00:00\",\"description\":\"Thermodynamic solubility assay providing reliable equilibrium solubility measurements to support absorption and formulation decisions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/technical-note\\\/thermodynamic-solubility-assay-validation\\\/#breadcrumb\"},\"inLanguage\":\"fr-CA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/technical-note\\\/thermodynamic-solubility-assay-validation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/technical-note\\\/thermodynamic-solubility-assay-validation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/image-5.webp\",\"contentUrl\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/image-5.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/technical-note\\\/thermodynamic-solubility-assay-validation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/page-daccueil\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Thermodynamic Solubility\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/\",\"name\":\"Sygnature Discovery\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/#organization\"},\"alternateName\":\"Sygnature\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-CA\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/#organization\",\"name\":\"Sygnature\",\"url\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/Logo.svg\",\"contentUrl\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/Logo.svg\",\"width\":1,\"height\":1,\"caption\":\"Sygnature\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sygnaturediscovery.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Thermodynamic Solubility: Equilibrium Across Biorelevant Media","description":"Thermodynamic solubility assay providing reliable equilibrium solubility measurements to support absorption and formulation decisions.","robots":{"index":"noindex","follow":"follow"},"og_locale":"fr_CA","og_type":"article","og_title":"Thermodynamic Solubility: Equilibrium Across Biorelevant Media","og_description":"Thermodynamic solubility assay providing reliable equilibrium solubility measurements to support absorption and formulation decisions.","og_url":"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/","og_site_name":"Sygnature","article_modified_time":"2026-02-02T17:25:41+00:00","og_image":[{"width":847,"height":462,"url":"https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimation du temps de lecture":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/","url":"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/","name":"Thermodynamic Solubility: Equilibrium Across Biorelevant Media","isPartOf":{"@id":"https:\/\/www.sygnaturediscovery.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/#primaryimage"},"image":{"@id":"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5.webp","datePublished":"2026-02-02T17:21:54+00:00","dateModified":"2026-02-02T17:25:41+00:00","description":"Thermodynamic solubility assay providing reliable equilibrium solubility measurements to support absorption and formulation decisions.","breadcrumb":{"@id":"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/#breadcrumb"},"inLanguage":"fr-CA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/"]}]},{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/#primaryimage","url":"https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5.webp","contentUrl":"https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2026\/02\/image-5.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.sygnaturediscovery.com\/fr\/technical-note\/thermodynamic-solubility-assay-validation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sygnaturediscovery.com\/fr\/page-daccueil\/"},{"@type":"ListItem","position":2,"name":"Thermodynamic Solubility"}]},{"@type":"WebSite","@id":"https:\/\/www.sygnaturediscovery.com\/fr\/#website","url":"https:\/\/www.sygnaturediscovery.com\/fr\/","name":"Sygnature Discovery","description":"","publisher":{"@id":"https:\/\/www.sygnaturediscovery.com\/fr\/#organization"},"alternateName":"Sygnature","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sygnaturediscovery.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-CA"},{"@type":"Organization","@id":"https:\/\/www.sygnaturediscovery.com\/fr\/#organization","name":"Sygnature","url":"https:\/\/www.sygnaturediscovery.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/www.sygnaturediscovery.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2025\/11\/Logo.svg","contentUrl":"https:\/\/www.sygnaturediscovery.com\/wp-content\/uploads\/2025\/11\/Logo.svg","width":1,"height":1,"caption":"Sygnature"},"image":{"@id":"https:\/\/www.sygnaturediscovery.com\/fr\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.sygnaturediscovery.com\/fr\/wp-json\/wp\/v2\/technical-note\/13517","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sygnaturediscovery.com\/fr\/wp-json\/wp\/v2\/technical-note"}],"about":[{"href":"https:\/\/www.sygnaturediscovery.com\/fr\/wp-json\/wp\/v2\/types\/technical-note"}],"version-history":[{"count":0,"href":"https:\/\/www.sygnaturediscovery.com\/fr\/wp-json\/wp\/v2\/technical-note\/13517\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.sygnaturediscovery.com\/fr\/wp-json\/wp\/v2\/media?parent=13517"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sygnaturediscovery.com\/fr\/wp-json\/wp\/v2\/category?post=13517"},{"taxonomy":"resource_tag","embeddable":true,"href":"https:\/\/www.sygnaturediscovery.com\/fr\/wp-json\/wp\/v2\/resource_tag?post=13517"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}